KD-Pyroshock
Pyroshock tester
Description
| Model | KD-Pyroshock-2040 | KD-Pyroshock-3040 | KD-Pyroshock-7575 | KD-Pyroshock-100100 | |
|---|---|---|---|---|---|
| Table Dimension (cm) | 20 x 40 | 30 x 40 | 750 x 750 | 1,000 x 1,000 | |
| Table Matrix Holes (mm) | Pith:50 mm with M8 | Pith:50 mm with M8 | Pith:100 mm with M10 | Pith:100 mm with M10 | |
| Max. Load (kg) | ≤ 30 | ≤ 30 | ≤ 150 | ≤ 30 | |
| SRS Frequency range (Hz) | 100 – 10,000 | 100 – 5,000 | 100 – 5,000 | 100 – 10,000 | |
| Max. acceleration (g) | 1,000 | 2,000 | 1,000 | 1,200 | |
| Tolerance (dB) | Before 3,000 Hz : ± 6 dB ; After 3,000 Hz : + 9 dB / - 6 dB | ||||
| System Weight (kg) | 3,500 | 3,800 | 5,800 | 11,000 | |
| System Dimension (mm) | (W) mm | 2,040 | 1,400 | 1,600 | 2,000 |
| (D) mm | 700 | 974 | 1,275 | 1,524 | |
| (H) mm | 1,200 | 1,680 | 1,970 | 1,938 | |
| Controller | KDI Standard | ||||
| Power Requirement | 220 V 1 phase / Air source | ||||